GC-2014 - Options
Gas Chromatograph for versatile applications
A Full Line of Injection Units and Compact, High-Sensitivity Detectors
Injection Units DINJ-2014
Dual Packed Injection Unit
Designed for Dual FID and TCD analyses. Because two flow paths are handled
using one temperature control port, these count as one heated zone.
SPL-2014 Split/Splitless Injection Unit
Standard unit for high-speed analysis with a narrow bore column. The gas saver function restricts the total gas used. High-pressure injection standard
SINJ-2014 Single Packed Injection Unit
This is a specialized sample injection unit for use with ECD or other high sensitivity detectors.
WBI-2014 Direct Injection Unit
Incorporates a septum purge flow path to restrict solvent tailing. Sharing glass inserts with splitless analysis simplifies parts requirements (patented).
Detectors
FID-2014
Flame Ionization Detector
Automatic ignition and re-ignition functions are standard. By mounting an APC or solenoid valve unit, a feedback function cuts off gas supply when the hydrogen flame is extinguished. Generally used for detection of organic compounds with a hydrogen carbon bond. Single and dual FID's arele. availa
TCD-2014
Thermal Conductivity Detector
The TCD-2014 is a semi-diffusion type cell reducing contamination and increasing cell lifetimes. Incorporates an automatic filament protection circuit. The TCD-2014 is used for analysis of inorganic gases and concentrated organic compounds.
ECD-2014
Electron Capture Detector
This cell is very similar to the ECD-14; so spare radiation sources can be shared. This detector is used for analysis of electrophillic compounds. Improved cell insulation and reduces contamination achieving higher sensitivity.
FPD-2014
Flame Photometric Detector
The FPD-2010, the nozzle system was updated to provide support for packed column analysis while maintaining its high sensitivity. The FPD-2014 is compact with a high maximum temperature (350deg.C). This detector is used for analysis of organic sulphur compounds and organic phosphorus compounds such as residual pesticides and malodorous components.
FTD-2014
Flame Thermionic Detector
Packed column analysis is supported by the FTD-2014 using the FTD-14 mechanism and collectors from both the FTD-14 and -17. Used for analysis of organic nitrogen compounds and organic phosphorus compounds such as residual pesticides.
FTD-2014C
Flame Thermionic Detector
This specialized capillary-type detector employs the FTD-2010 mechanism. Used for analysis of organic nitrogen compounds and organic phosphorus compounds such as residual pesticides. The new collector construction allows replacement without tools. An optional alkali source regeneration kit recoats the bead reducing running costs.
GC Software
-
Waters Empower chromatography data systems can now be used to control AOC-30 autoinjectors in Shimadzu Nexis™ GC-2030 systems and perform packed column analysis. Space-saving AOC-30 systems offer reliable and long-term performance, and support capillary/packed column analysis using only a single GC-2030 system.
-
Enables Shimadzu Gas Chromatographs to be Controlled by Thermo Scientific's Chromeleon Chromatography Data System Software.
-
The Calorific Calculation Software can automatically calculate calorific values and generate reports that comply with BTU and ISO 6976. In addition, the target gas can be registered according to the customer’s requirement.
-
Agilent OpenLab CDS chromatography data systems can now be used to control AOC-30 autoinjectors in Shimadzu Nexis™ GC-2030 systems and perform packed column analysis. Space-saving AOC-30 systems offer reliable and long-term performance, and support capillary/packed column analysis using only a single GC-2030 system.
LabSolutions Series
-
LabSolutions CS features an innovative operating environment and provides complete data management to ensure secure information in networked laboratories.
-
LabSolutions DB has a data management function and is compliant with the ER/ES Regulations. It is optimally configured for customers using a PC.
Related information
-
Simultaneous Three-Column Analysis with a Single Sample Injection.
-
The HS-10 headspace sampler is highly cost efficient, yet is equipped with advanced features such as a mixing function and the ability to heat-ahead the sample vials waiting for analysis.
-
The SLS-2020 GC system sample line selector can connect up to 12 gas lines used for analysis.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
The AOC-20 Series is the perfect solution for automated analyses.
-
GC Consumables are designed to complement your Shimadzu GC Systems.
-
An AGE-1000 air gas purifier can be used to remove hydrocarbons from compressor air in order to generate compressed air with hydrocarbon levels lower than Grade 1 high-purity gas (hydrocarbon concentration of 100 ppb).
-
Impurities in gases, such as hydrocarbons, moisture and oxygen, can contaminate the gas line and instrument, cause column degradation and affect the accuracy of your analysis results, which may lead to instrument downtime.
-
Gas compositions produced in refinery plants consist of hydrocarbons, permanent gases, H2S, etc.
-
Recently, natural gas has been recognized as a clean resournce for energy, in addition to being a raw material for chemical products.
-
It is necessary to analyze outgas in transformer insulation oil in power plant facilities.
-
High-purity gas is necessary in industries such as chemical, medical, and foods.
-
Periodical monitoring of calorific values is necessary to ensure a stable supply of town gas. Since Shimadzu’s system GC is robust and designed for automated analysis, it is widely used for 24 hour/day online analysis in this field.
-
Some sulfur compounds are known to be not only hazardous but also catalytic poisons.
-
A gas chromatograph is used for impurity analysis of intermediate or final products in various chemical fields.
-
Gas chromatographs help analyze green house gases in air and soil.
-
With LabSolutions LCGC, both LC and GC systems are operated from the same software, enabling simultaneous control of multiple instruments from a single PC.
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-