CGT-7100 - Specs
Transportable Gas Analyzer
Type 1
Applications |
Combusion Equipment Test / Research |
---|---|
Measured Components |
CO, CO2 |
Measurement range |
CO: 0 to 1000/5000 ppm |
Measurement principle |
CO, CO2, CH4: Single light source dual beam non-dispersive infrared absorption method |
Repeatability |
Within ±0.5% of full scale |
Zero Drift |
Within ±1% of full scale per day |
Span Drift |
Within ±1% of full scale per day |
Linearity |
Within ±2% of full scale |
Response Time (Note 1) |
CO, CO2, CH4: Selectable from 15, 30, or 60 seconds |
Sample Gas Flow Rate |
Approx. 2.5 L/min (The gas flow rate for the sample cell is 1.0 L/min.) |
Display |
LCD. Allows a simultaneous display of 3 items. |
Transmission Output |
0-1 V DC, 3-channel insulated output (non-insulated between channels) |
Wireless Signal Output (Note 2) |
Yes |
Data Storage toExternal Media (Note 2) |
Allows data in CSV format to be saved to a USB flash drive. |
Permitted Ambient Temperature |
5-40°C. Should be protected from direct sunlight and radiant heat. |
Power Requirements |
110 V, 115 V, 120 V, 127 V, 220 V, 230 V, 240 V AC, 50-60 Hz, max. 150 VA |
Dimensions |
W260 x H452 x D420 mm (Excluding protrusions) |
Weight (Main unit) |
Approx. 16 kg |
External drain separator |
Yes |
Sample Gas Conditions(Note 3) |
At the CGT-7100 main unit inletPressure: -980 to +980 PaTemperature: Ambient temperature |
External Signal Input |
0-1 V DC, 1 channel, signal input from an external analyzer, display |
Note 1: Response time is measured from the point the gas enters the sample gas inlet until 90% response is indicated (flow line purge time plus electrical system response time).
Note 2: The smart devices and USB flash drives on which operation has been validated are shown below in "Operation Validated."
Note 3: If conditions are not satisfied, contact a Shimadzu representative. If a mist absorber set (option) is used, then an SO3 mist can be used up to about 30 ppm. If the concentration of a component other than N2 is 30 vol% or more, then measurement specifications might not be satisfied in some cases.
Type 2
Applications |
Fuel Cell Research |
---|---|
Measured Components |
CO, CH4 |
Measurement range |
CO: 0 to 5 vol% |
Measurement principle |
CO, CO2, CH4: Single light source dual beam non-dispersive infrared absorption method |
Repeatability |
Within ±0.5% of full scale |
Zero Drift |
Within ±1% of full scale per day |
Span Drift |
Within ±1% of full scale per day |
Linearity |
CO: Within ±2% of full scaleCH4: Within ±3% of full scale |
Response Time (Note 1) |
CO, CO2, CH4: Selectable from 15, 30, or 60 seconds |
Sample Gas Flow Rate |
Approx. 2.5 L/min (The gas flow rate for the sample cell is 1.0 L/min.) |
Display |
LCD. Allows a simultaneous display of 3 items. |
Transmission Output |
0-1 V DC, 3-channel insulated output (non-insulated between channels) |
Wireless Signal Output (Note 2) |
Yes |
Data Storage toExternal Media (Note 2) |
Allows data in CSV format to be saved to a USB flash drive. |
Permitted Ambient Temperature |
5-40°C. Should be protected from direct sunlight and radiant heat. |
Power Requirements |
110 V, 115 V, 120 V, 127 V, 220 V, 230 V, 240 V AC, 50-60 Hz, max. 150 VA |
Dimensions |
W260 x H452 x D420 mm (Excluding protrusions) |
Weight (Main unit) |
Approx. 16 kg |
External drain separator |
No |
Sample Gas Conditions(Note 3) |
At the CGT-7100 main unit inletPressure: -980 to +980 PaTemperature: Ambient temperature |
External Signal Input |
0-1 V DC, 1 channel, signal input from an external analyzer, display |
Type 3
Applications |
Catalyst Research |
---|---|
Measured Components |
CO, CO2 |
Measurement range |
CO: 0 to 10/20 vol% |
Measurement principle |
CO, CO2, CH4: Single light source dual beam non-dispersive infrared absorption method |
Repeatability |
Within ±0.5% of full scale |
Zero Drift |
Within ±1% of full scale per day |
Span Drift |
Within ±1% of full scale per day |
Linearity |
Within ±2% of full scale |
Response Time (Note 1) |
Less than 3 minutes(at a sample gas flow rate of 100 mL/min) |
Sample Gas Flow Rate |
100 to 400 mL/min (variable) |
Display |
LCD. Allows a simultaneous display of 3 items. |
Transmission Output |
0-1 V DC, 3-channel insulated output (non-insulated between channels) |
Wireless Signal Output (Note 2) |
Yes |
Data Storage toExternal Media (Note 2) |
Allows data in CSV format to be saved to a USB flash drive. |
Permitted Ambient Temperature |
5-40°C. Should be protected from direct sunlight and radiant heat. |
Power Requirements |
110 V, 115 V, 120 V, 127 V, 220 V, 230 V, 240 V AC, 50-60 Hz, max. 150 VA |
Dimensions |
W260 x H452 x D420 mm (Excluding protrusions) |
Weight (Main unit) |
Approx. 16 kg |
External drain separator |
No |
Sample Gas Conditions(Note 3) |
At the CGT-7100 main unit inletPressure: -980 to +980 PaTemperature: Ambient temperature |
External Signal Input |
0-1 V DC, 1 channel, signal input from an external analyzer, display |