EHF-T Series - Specs
Torsional Dynamic and Fatigue Testing System
EHF-TV05kNm-010
Maximum capacity : Dynamic / static |
±0.5/±0.75kN/m |
---|---|
Loading Method |
Electric-hydraulic servo (cross-looped system) |
Max. torsion angle |
±50 deg |
Cycle speed and amplitude (sine wave) |
See amplitude characteristics charts. |
Control mode |
Torque control and torsion angle control |
Static accuracy : Torque |
Within ±1 % of indicated value or within ±0.05 % of dynamic rating, whichever is greater |
Static accuracy : Torsion angle |
Within ±1.5 % of indicated value or within ±0.15 % of dynamic rating, whichever is greater |
Loading frame (testing space) : S : Flange spacing |
0 to 1000 mm |
Loading frame (testing space) : H : Height at center of torque |
300mm |
Loading frame (testing space) : F×E : Table area(width × length) |
600×1800mm |
Loading frame (testing space) : G : Base stand height |
600mm |
Loading frame (testing space) : M : T-slot size (nominal) |
18mm |
Loading frame (testing space) : Weight (including actuator) |
About 830 kg |
Hydraulic power supply unit used : Model |
QF-10B |
EHF-TV1kNm-020
Maximum capacity : Dynamic / static |
±1/±1.5kN/m |
---|---|
Loading Method |
Electric-hydraulic servo (cross-looped system) |
Max. torsion angle |
±50 deg |
Cycle speed and amplitude (sine wave) |
See amplitude characteristics charts. |
Control mode |
Torque control and torsion angle control |
Static accuracy : Torque |
Within ±1 % of indicated value or within ±0.05 % of dynamic rating, whichever is greater |
Static accuracy : Torsion angle |
Within ±1.5 % of indicated value or within ±0.15 % of dynamic rating, whichever is greater |
Loading frame (testing space) : S : Flange spacing |
0 to 1000 mm |
Loading frame (testing space) : H : Height at center of torque |
300mm |
Loading frame (testing space) : F×E : Table area(width × length) |
700×1800mm |
Loading frame (testing space) : G : Base stand height |
600mm |
Loading frame (testing space) : M : T-slot size (nominal) |
22mm |
Loading frame (testing space) : Weight (including actuator) |
Approx. 950 kg |
Hydraulic power supply unit used : Model |
QF-20B |
EHF-TV2kNm-040
Maximum capacity : Dynamic / static |
±2/±3kN/m |
---|---|
Loading Method |
Electric-hydraulic servo (cross-looped system) |
Max. torsion angle |
±50 deg |
Cycle speed and amplitude (sine wave) |
See amplitude characteristics charts. |
Control mode |
Torque control and torsion angle control |
Static accuracy : Torque |
Within ±1 % of indicated value or within ±0.05 % of dynamic rating, whichever is greater |
Static accuracy : Torsion angle |
Within ±1.5 % of indicated value or within ±0.15 % of dynamic rating, whichever is greater |
Loading frame (testing space) : S : Flange spacing |
0 to 1000 mm |
Loading frame (testing space) : H : Height at center of torque |
350mm |
Loading frame (testing space) : F×E : Table area(width × length) |
800×2000mm |
Loading frame (testing space) : G : Base stand height |
700mm |
Loading frame (testing space) : M : T-slot size (nominal) |
22mm |
Loading frame (testing space) : Weight (including actuator) |
Approx. 1700 kg |
Hydraulic power supply unit used : Model |
QF-40B |
EHF-TV5kNm-070
Maximum capacity : Dynamic / static |
±5/±7.5kN/m |
---|---|
Loading Method |
Electric-hydraulic servo (cross-looped system) |
Max. torsion angle |
±50 deg |
Cycle speed and amplitude (sine wave) |
See amplitude characteristics charts. |
Control mode |
Torque control and torsion angle control |
Static accuracy : Torque |
Within ±1 % of indicated value or within ±0.05 % of dynamic rating, whichever is greater |
Static accuracy : Torsion angle |
Within ±1.5 % of indicated value or within ±0.15 % of dynamic rating, whichever is greater |
Loading frame (testing space) : S : Flange spacing |
0 to 1000 mm |
Loading frame (testing space) : H : Height at center of torque |
400mm |
Loading frame (testing space) : F×E : Table area(width × length) |
800×2200mm |
Loading frame (testing space) : G : Base stand height |
700mm |
Loading frame (testing space) : M : T-slot size (nominal) |
22mm |
Loading frame (testing space) : Weight (including actuator) |
Approx. 3200 kg |
Hydraulic power supply unit used : Model |
QF-70B |
EHF-TV10kNm-110
Maximum capacity : Dynamic / static |
±10/±15kN/m |
---|---|
Loading Method |
Electric-hydraulic servo (cross-looped system) |
Max. torsion angle |
±50 deg |
Cycle speed and amplitude (sine wave) |
See amplitude characteristics charts. |
Control mode |
Torque control and torsion angle control |
Static accuracy : Torque |
Within ±1 % of indicated value or within ±0.05 % of dynamic rating, whichever is greater |
Static accuracy : Torsion angle |
Within ±1.5 % of indicated value or within ±0.15 % of dynamic rating, whichever is greater |
Loading frame (testing space) : S : Flange spacing |
0 to 1200 mm |
Loading frame (testing space) : H : Height at center of torque |
400mm |
Loading frame (testing space) : F×E : Table area(width × length) |
1000×2500mm |
Loading frame (testing space) : G : Base stand height |
Base stand is optional. |
Loading frame (testing space) : M : T-slot size (nominal) |
22mm |
Loading frame (testing space) : Weight (including actuator) |
Approx. 3200 kg (excluding base stand) |
Hydraulic power supply unit used : Model |
QF-110B |